Task Force Tips AU6P7T Task Force Tips Fire Fighting Equipment Nozzles, Monitors, Piercing Nozzles, Manifold, Ball Intake Valves, PRO/pak, Blitzfire and Suction Hose
New User?   Products  
Product Details
AU6P7T
HYDRANT MASTER


Part No:AU6P7T


 Details
HYDRANT MASTER
The Hydrant Master is a lightweight, low friction-loss hydrant valve that can be used in many water supply operations. Water pressure from opening the hydrant automatically turns on the Hydrant Master electronics. The valve opens and closes under radio control with an innovative slide valve which allows the control of high flows with a device that only weighs 31 pounds and consumes extremely low power. A handheld controller with pressure display and positive feedback of valve position controls the valve in excess or 1200 feet (366 m) away and allows hydrant pressure to be monitored remotely from the fire scene. Both the valve and handheld are equipped with backlighting for use in low-light situations. Manual override is provided on the valve control panel. The radio used is of the spread spectrum variety (like wifi) such that no license is required. The valve and handheld are both powered by (4) AA lithium batteries which will provide 140 hours of reliable operation. A low battery indicator will light at both the valve and at the hand held controller when 20 hours of battery life remain. The unit will go into power save sleep more after five minutes of operation without a button being pressed.

Weight: 31.000 lbs ( kg)

Coupling Size Side A 4.0 Inch (100mm)
Coupling Size Side B 5.0 inch (125mm)
Coupling Swiveling/Rigid Side A F Long Handle Swivel
Coupling Swiveling/Rigid Side B Male Rigid
Finish Powdercoated Stardust Silver
Material Aluminum
Operation Energy Source Hydraulic/Battery Power
Valve Actuation Method Remote Control
Valve Design Slide Valve (Aluminum)
Water Flow Style RC Hydrant Valve
Waterway Size 4.5 Inch (115mm)


     Related Videos   
    Hydrant Master Video

    COPY URL LINK BELOW AND PASTE IT INTO AN EMAIL TO SHARE




 
•   VALVE SPECIFICATIONS
Main LDH Waterway size (at valve seat): 4.5” (114 mm)
Minimum Operating Pressure: 5 psi (0.7 Bar) NOT FOR SUCTION USE.
Maximum Operating Pressure: 300 psi (20 bar)
Hydrostatic Proof Test Pressure: 900 psi (62 bar)
Temperature Rating*: -25°F to 135°F (-32°C to 57°C)
Batteries: 4 AA batteries, Lithium recommended
Expected valve battery life: 140 hours lithium, 100 hours alkaline
*For temperatures below 32°F (0°C), valves must be drained after use to avoid damage.



Task Force Tips ® is a registered trademark of Task Force Tips, Inc.
TFT ® is a registered trademark of Task Force Tips, Inc.